5.13.14 Maximum Measurement Time of the Realtime Profile 
(1) Maximum measurement time 
 
The timer used for performance measurement is comprised of a 40-bit counter. The maximum measurement time varies with 
the unit of measurement selected. 
To select a unit of measurement, specify it in the Measurement interval drop-down list of the Properties dialog box. 
The measurable maximum times are listed below. 
 
Table 5.43 Maximum measurement time 
No. Resolution 
Maximum 
measurement 
time 
10ns 
Approx. 3 hours, 03 minutes, 15 seconds 
20ns 
Approx. 6 hours, 06 minutes, 30 seconds 
40ns 
Approx. 12 hours, 13 minutes, 00 seconds 
80ns 
Approx. 24 hours, 26 minutes, 00 seconds 
160ns 
Approx. 48 hours, 52 minutes, 01 seconds 
1.6us 
Approx. 488 hours, 40 minutes, 18 seconds 
 
CAUTION 
Note that performance measurement produces an error of ± “2 resolution + 100 ns” (when resolution = 20 ns, ±140 ns) 
whenever entering functions. If the resolution is 20 ns and you enter functions 10 times, ±1400 ns error occurs. 
 
(2) Maximum measurement count 
Execution counts of the realtime profile are measured using a 16-bit counter. Measurement can be taken of up to a count of 
65,535.