2.4 Connecting the PC4701 
To connect the emulation pod to the PC4701, use the FLX120-RPD 120-pin flexible cable included with this product package. 
Connect the PC4701 side connector of the FLX120-RPD to the cable connector of the PC4701, then secure with screws the 
FLX120-RPD. 
 
2.4.1 Connecting the Cable to the PC4701 
Figure 2.2 shows how to connect the PC4701 and FLX120-RPD. 
 
 
 
 
Figure 2.2 Connecting the cable to the PC4701 
 
  CAUTION
 
Note on Connecting the PC4701 and FLX120-RPD: 
 
 
Always shut OFF power before connecting the cable. Otherwise, the internal circuits may be damaged. 
 
 
IMPORTANT 
Notes on Connecting the Cable and Securing the Screws: 
 
 
To connect the FLX120-RPD, be sure to hold the both sides of the PC4701 side connector horizontally with the 
"UPSIDE" facing up. 
 
After connecting the cable to the emulator main unit PC4701, be sure to secure the screws mounted in both 
sides of the connector. 
 
 
Emulator main unit
PC4701 side connector 
of FLX120-RPD
Secure this screw.
UPSIDE should be face up .
 
Secure this screw.