M306NKT3-RPD-E User’s Manual 
2. Setup 
REJ10J0326-0400 Rev.4.00 Sep. 01, 2006 
 
Page 34 of 104 
 
 
2.8.3 Connecting to a 100-pin 0.65mm pitch Foot Pattern (Part 2) 
Figure 2.11 shows how to connect a 100-pin 0.65mm pitch foot pattern on the user system to the M3T-DIRECT100S (not 
included), and here following is its procedure. 
For details on the M3T-100LCC-DMS (not included) and M3T- DIRECT100S (not included), refer to each user's manual. 
 
(1) Attach the M3T- DIRECT100S to the user system. 
(2) Attach the M3T-100LCC-DMS to the M3T-DIRECT100S. 
(3) Attach the CN2 side of the M30800T-PTC to the CN2 side of the package converter board connected to the emulation pod 
probe. 
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS. 
 
 
Figure 2.12 Connecting to a 100-pin 0.65mm pitch foot pattern (2/3) 
 
  CAUTION
 
Note on Connecting the User System: 
 
 
Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulation 
pod. 
 
The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal iterations. 
 
The connectors of the M3T-100LCC-DMS and M3T-DIRECT100S are guaranteed for only 20 
insertion/removal iterations. 
 
M3T-100LCC-DMS
(not included)
CN2 side
(3)
(4)
M30800T-PTC
(2)
(1)
100-pin 0.65mm pitch
(PRQP0100JB-A) foot pattern
No. 1 pin
User system
M3T-DIRECT100S
(not included)
Package converter board