2.8.6 Connecting to a 100-pin 0.5mm pitch Foot Pattern (Part 2) 
Figure 2.15 shows how to connect a 100-pin 0.5mm pitch foot pattern on the user system to the M3T-100LCC-QSD (not 
included), and here following is its procedure. 
For details on the M3T-100LCC-QSD (not included), refer to its user's manual. 
 
(1)  Attach the TQPACK100SD to the user system. 
(2)  Attach the TQSOCKET100SDG to the TQPACK100SD. 
(3)  Attach the M3T-100LCC-QSD to the TQSOCKET100SDG. 
(4) Attach the CN2 side of the M30800T-PTC to the CN2 side of the package converter board connected to the emulation pod 
probe. 
(5) Attach the M30800T-PT to the M3T-100LCC-QSD. 
 
 
 
Figure 2.15 Connecting to a 100-pin 0.65mm pitch foot pattern (2/2) 
 
 
  CAUTION
 
Note on Connecting the User System: 
 
 
Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulation 
pod. 
 
The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal iterations. 
 
The connectors of the M3T-100LCC-QSD are guaranteed for only 20 insertion/removal iterations. 
 
M3T-100LCC-QSD
(not included)
CN2 side
(4)
(5)
M30800T-PTC
(3)
(2)
TQSOCKET100SDG
TQPACK100SD
Package converter board
Tip of emulation pod probe
(1)
100-pin 0.5mm pitch
(PLQP0100KB-A) foot pattern
No. 1 pin
User system