M306NKT3-RPD-E User’s Manual 
3. Usage (How to Use the Emulator Debugger)   
REJ10J0326-0400 Rev.4.00 Sep. 01, 2006 
 
Page 67 of 104 
 
3.7 Trace Window 
 
The trace window is used to show the results of real-time trace measurements. 
 
(1) Trace window 
1) Opening the trace window 
 
 
 
Trace window 
Clicking this button opens the trace window. 
 
2) Trace window 
 
Trace window 
The trace window is used to show the results of real-time trace 
measurements. It has the following four display modes. Mixed 
mode also can be displayed. 
- Bus 
mode
 
 
Bus information per cycle can be inspected. The contents are 
displayed in order of execution paths. 
- Disassemble 
mode 
The execution paths of the executed instructions can be 
inspected. The contents are displayed in order of execution 
paths. 
- Source 
mode
 
 
The execution paths of the source program can be inspected. 
-  Data access mode
 
 
Data read/write cycles can be inspected 
 
The trace window shows the measurement result when a 
real-time trace measurement has finished. The trace window 
remains blank until the real-time trace measurement in progress 
finishes.