Renesas M3T-MR100 用户手册

下载
页码 304
   
- 150 - 
 
5.9  Time Management Function 
Specifications of the time management function of MR100 are listed in Table 5.17
Table 5.17 Specifications of the Time Management Function 
No.  
Item 
Content 
System time value 
Unsigned 48 bits 
Unit of system time value 
 1[ms]   
System time updating cycle 
User-specified time tick updating time [ms] 
Initial value of system time (at initial startup) 
  000000000000H     
 
Table 5.18 List of Time Management Function Service Call   
System State 
No. Service 
Call 
Function 
T N E D  U L 
1 get_tim 
[S] 
○ 
 
○ 
○ 
○ 
2 iget_tim 
 
Reference system time 
 
○ 
○ 
○ 
○ 
3 set_tim 
[S] 
○ 
 
○ 
○ 
○ 
4 iset_tim 
 
Set system time 
 
○ 
○ 
○ 
○ 
5 isig_tim 
[S] 
Supply a time tick 
 
○ 
○ 
○ 
○ 
 
  Notes: 
• 
[S]: Standard profile service calls 
[B]: Basic profile service calls 
• 
Each sign within " System State " is a following meaning.   
♦  T: Can be called from task context 
♦  N: Can be called from non-task context 
♦  E: Can be called from dispatch-enabled state 
♦  D: Can be called from dispatch-disabled state 
♦  U: Can be called from CPU-unlocked state 
♦  L: Can be called from CPU-locked state