Renesas M3T-MR100 用户手册

下载
页码 304
   
- 162 - 
 
5.11 Time Management Function (Alarm Handler) 
Specifications of the alarm handler function of MR100 are listed in Table 5.21. The alarm handler description languages in 
item No. 4 are those specified in the GUI configurator. They are not output to a configuration file, nor are the MR100 ker-
nel concerned with them. 
 
Table 5.21 Specifications of the Alarm Handler Function 
No. Item 
Content 
1 Alarm 
handler 
ID 
1-255 
Activation time 
0-7fffffff [ms] 
Extended information 
16 bits 
TA_HLNG: 
Handlers written in high-level language 
4 Alarm 
handler 
attribute 
TA_ASM:   
Handlers written in assembly language 
 
Table 5.22 List of Alarm Handler Function Service Call 
System State 
No. Service 
Call 
Function 
T N E D U
1 sta_alm 
 
 
○ 
○ 
2 ista_alm 
 
Starts alarm handler operation 
 
○ 
○ 
3 stp_alm 
 
 
○ 
○ 
4 istp_alm 
 
Stops alarm handler operation 
 
○ 
○ 
5 ref_alm 
 
 
○ 
○ 
6 iref_alm 
 
References alarm handler status 
 
○ 
○ 
 
  Notes: 
• 
[S]: Standard profile service calls 
[B]: Basic profile service calls 
• 
Each sign within " System State " is a following meaning.   
♦  T: Can be called from task context 
♦  N: Can be called from non-task context 
♦  E: Can be called from dispatch-enabled state 
♦  D: Can be called from dispatch-disabled state 
♦  U: Can be called from CPU-unlocked state 
♦  L: Can be called from CPU-locked state