Warning messages 
The following message are a warning. A warning can be ignored providing that its content is understood. 
cfg100 Warning : system is not defined (xxxx.cfg) 
cfg100 Warning : system.XXXX is not defined (xxxx.cfg) 
System definition or system definition item XXXX is omitted in the configuration file. 
cfg100 Warning : task[x].XXXX is not defined near line xxx (xxxx.cfg) 
The task definition item XXXX in ID number is omitted. 
cfg100 Warning : Already definition XXXX  near line xxx (xxxx.cfg) 
XXXX has already been defined.The defined content is ignored, check to delete the extra definition. 
cfg100 Warning : interrupt_vector[x]'s default is not defined (default.cfg) 
The interrupt vector definition of vector number x in the default configuration file is missing. 
cfg100 Warning : interrupt_vector[x]'s default is not defined near line xxx (xxxx.cfg) 
The interrupt vector of vector number x in the configuration file is not defined in the default configuration file. 
cfg100 Warning : Initial start task is not defined 
The task of task ID number 1 was defined as the initial startup task because no initial startup task is defined in 
the configuration file. 
cfg100 Warning : system.stack_size is an uneven number near line xxx 
cfg100 Warning : task[x].stack_size is an uneven number near line xxx 
 
Please set even size in system.stack_size or task[x].stack_size. 
cfg100 Warning : system_IPL should be 7 
When "-Wipl" is specified as the command option of KONFIGYURETA, you should make the value of sys-
rem_IPL of a system definition 7. 
cfg100 Warning : Timer counter value is less than your settimg time 
The error occurred in the operation of a timer count. Please check whether an error is permitted. 
cfg100 Warning : XXXX is specified as YYYY. 
XXXX is specified as YYYY.