(4) When the Program Window is Not Displayed Normally
Table 6.3 Checkpoints of errors when starting up the emulator debugger
Error
The emulation pod is not connected to the
target system.
The emulation pod cannot be connected to
the target system.
Communication error occurred.
Data was not sent to the target.
Communication error occurred.
Data was not received from the target.
Target system cannot be properly built.
M3T-PD38 version is not the same version
as the firmware in the target.
Target MCU cannot be reset.
Reset the target system.
Checkpoint
• The emulator system and host are not communicating
normally.
Check the connection between the emulator and the
host machine.
Check the I/F switch on the rear of the emulation pod.
Check the I/F setting of the Init dialog.
Check the description of the environment setting file
(.ini) and startup option.
• The emulator system is not operating properly.
Download the proper firmware.
See "4.2 Downloading Firmware" (page 34).
• Recheck the connection between the PC4701 and this
product.
See "3.3 Connecting the PC4701" (page 22).
• The firmware is not compliant with the emulation pod.
Download the proper firmware.
See "4.2 Downloading Firmware" (page 34).
• The MCU reset control performed inside the emulator
was not processed normally.
See "3.7 Reset Circuit of the Target System" (page 30).
See "6.2 When an Error Message "Cannot be reset" is
Displayed" (page 45).