2.8.2 Connecting to a 100-pin LCC socket
Figure 2.10 shows how to connect a 100-pin LCC socket (IC61-1004-051 of Yamaichi Electronics Co., Ltd.) on the user
system to the M30800T-PTC (included).
(1) Attach the CN2 side of the M30800T-PTC to the CN2 side of the package converter board connected to the emulation pod
probe.
(2) Attach the M30800T-PTC to the 100-pin LCC socket.
100- pin LCC socket
CN 2 side
(1)
No . 1 pin
(2)
M 30800T- PTC
User system
Package converter board
Tip of emulation pod probe
Figure 2.10 Connecting to a 100-pin LCC socket
CAUTION
Note on Connecting the User System:
z
Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulation
pod.
IMPORTANT
Notes on Connectors of the Converter board:
z
The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal iterations.
z
The connectors of the IC61-1004-051 are guaranteed for only 20 insertion/removal iterations.
z
For purchasing the IC61-1004-051 or for technical information, contact Yamaichi Electronics Co., Ltd.