2.8.6 Connecting to a 100-pin 0.5mm Pitch Foot Pattern (Part 1)
Figure 2.14 shows how to connect a 100-pin 0.5mm pitch foot pattern on the user system to the M3T-F160-100NSD (not
included), and here following is its procedure. For details on the M3T-F160-100NSD (not included), refer to its user's manual.
(1) Attach the NQPACK100SD-ND included with the M3T-F160-100NSD to the user system.
(2) Attach the YQPACK100SD included with M3T-F160-100NSD to the NQPACK100SD-ND and secure it with the
YQ-GUIDE's.
(3) Attach the CN2 side of the M3T-F160-100NSD to the CN2 side of the package converter board connected to the emulation
pod probe.
(4) Attach the M3T-F160-100NSD to the YQPACK100SD.
*
CN 2 side
(3)
(1)
100- pin 0.5 mm pitch
( PLQP 0100 KB-A ) foot pattern
( PLQP 0100 KB-A ) foot pattern
No . 1 pin
User system
M 3T-F 160- 100 NSD
( not included)
FLASH MCU , etc.
On- board evaluation
*: These four items are available in one package
.
YQPACK 100 SD
NQPACK100 SD-ND
HQPACK 100 SD
( not included)
(2)
(4)
YQ - GUIDE (x4)
These corners are not round.
Package converter board
Tip of emulation pod probe
Figure 2.14 Connecting to a 100-pin 0.5mm pitch foot pattern (1/2)
CAUTION
Note on Connecting the User System:
z Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulation
pod.
IMPORTANT
Note on Connectors of the Converter board:
z The connectors of the M3T-F160-100NSD are guaranteed for only 50 insertion/removal iterations.