5. Connection Procedure (See Figure 3) 
 
The procedure for connecting the R0E5212L4CFG00 is shown 
below. 
 
(1)  Mount the NQPACK032SA on the user system. 
(2)  Attach the YQPACK032SA on the NQPACK032SA. 
(3) Secure the four corners of the YQPACK032SA with the 
YQ-GUIDE's. 
● Do not use the screws included with the 
YQPACK032SA for fixing the YQPACK032SA. 
● The screwdriver included with the NQPACK032SA is 
used for fixing the HQPACK032SA. Do not use it for 
fixing the YQ-GUIDE’s. 
(4) Attach the R0E521000EPB00 or  R0E521000CPE00 to the 
R0E5212L4CFG00. 
(5)  Attach the R0E5212L4CFG00 to the YQPACK032SA. 
 
 
(PLQP0032GB-A) foot pattern
YQ- GUIDE (x4)  
YQPACK0 32 SA  
NQPACK0 32 SA  
(1)
(2)
(4)
(5)
R0E5212L4CFG00
(3)
R 0E 521000 EPB 00 
or
R0 E 521000 CPE 00
Be sure to use a 
flathead screwdriver.
32-pin 0.8mm pitch
Figure 3 Connection procedure of the R0E5212L4CFG00 
 
 
6. External Dimensions and a Sample Foot Pattern (See Figure 4) 
 
 
Figure 4 External dimensions and a sample foot pattern of the R0E5212L4CFG00 
 
 
31.0
16
.5
32
.0
0.5
0.8
6.8
10.0
6.
8
10
.0
Unit: mm
R0E5212L4CFG00 REV.A