Renesas M3062PT2-EPB 用户手册

下载
页码 102
M3062PT2-EPB User’s Manual 
2. Setup 
REJ10J0868-0200  Rev.2.00  January 16, 2006 
 
 
2.11 Selecting Clock Supply 
2.11.1 Clocks 
You can choose a clock supplied to the evaluation MCU by the Emulator tab in the Init dialog box of the emulator debugger. 
Table 2.4 shows the clocks and their initial settings. 
 
Table 2.4 Clock supply to the MCU 
Clock 
Display of 
emulator debugger 
Description Default 
setting 
Internal 
Internal oscillator circuit board 
(OSC-3 or OSC-2) 
Yes 
External 
Oscillator circuit on the user system 
Main (X
IN
-X
OUT
Generate 
Internal generator circuit 
(1.0--16.0 MHz) 
Internal 
Internal oscillator circuit 
(32.768 kHz) 
Sub (X
CIN
-X
COUT
External 
Oscillator circuit on the user system 
Yes 
 
 
IMPORTANT 
Notes on Changing the Clock Supply: 
 
 
The clock supply can be set by the Init dialog box when starting up the emulator debugger or inputting CLK 
command on the script window. 
 
 
2.11.2 Using an Internal Oscillator Circuit Board 
(1)  Kinds of Oscillator Circuit Boards 
 
The PC7501 comes with an oscillator circuit board OSC-3 (30 MHz). And an oscillator circuit board OSC-3 (16 MHz) 
and an oscillator circuit board OSC-2 (bare board) are included with this product. If you use the internal oscillator 
circuit board OSC-3 (16 MHz) or OSC-2 of the PC7501 as a main clock, choose "Internal" in the emulator debugger 
after replacing oscillator circuit boards to change a clock supplied to an MCU. 
 
Page 44 of 102