Renesas M3062PT2-EPB 用户手册

下载
页码 102
M3062PT2-EPB User’s Manual 
3. Usage (How to Use the Emulator Debugger) 
REJ10J0868-0200  Rev.2.00  January 16, 2006 
 
3. Usage (How to Use the Emulator Debugger) 
 
This chapter describes how to start up the emulator debugger from the High-performance Embedded Workshop. 
 
3.1 Starting Up the Emulator Debugger 
When debugging the completed programs, switch the session. The session can be changed by the drop down list of the tool bar 
shown below. 
 
 
You will have as many sessions created as the number of targets you selected when creating a project, so select the session that 
corresponds to the target to be connected from the drop-down list. To connect to the PC7501 + M16C Emulation Probe, select 
“SessionM16C_R8C_PC7501_Emulator.” 
 
3.1.1 INIT Dialog Box 
After specifying the session, an Init dialog box to connect the target is displayed. The Init dialog box is used to set the items 
that need to be set when the emulator debugger starts up. The contents set in this dialog box remain effective the next time you 
start the debugger. When settings 1 to 4 have been finished, click “OK”. 
 
(1) MCU tab 
1 Specifying the MCU file 
 
Specifying the MCU file 
Specifying the MCU file 
(1) Click the “Refer…” button. 
(2) ”Select MCU File” dialog box will be displayed. 
Specify the MCU file “M16C62P_512.MCU” for the 
target MCU. 
 
-  The MCU file contains the information specific to the 
target MCU. 
-  The MCU file you have selected is displayed in the 
MCU section of the MCU tab. 
 
 
 
Page 49 of 102