Section 20   USB Function Module 
Rev. 4.00  Sep. 14, 2005  Page 768 of 982 
REJ09B0023-0400 
 
20.4.3 Control 
Transfer 
Control transfer consists of three stages: setup, data (not always included), and status (figure 20.4). 
The data stage comprises a number of bus transactions. Operation flowcharts for each stage are 
shown below. 
Control IN
Setup stage
Data stage
Status stage
Control OUT
No data
SETUP(0)
DATA0
SETUP(0)
DATA0
SETUP(0)
DATA0
IN(1)
DATA1
OUT(1)
DATA1
IN(0)
DATA0
OUT(0)
. . .
. . .
DATA0
IN(0/1)
DATA0/1
OUT(0/1)
DATA0/1
OUT(1)
DATA1
IN(1)
DATA1
IN(1)
DATA1
 
Figure 20.4   Transfer Stages in Control Transfer