Section 20   USB Function Module 
Rev. 4.00  Sep. 14, 2005  Page 776 of 982 
REJ09B0023-0400 
 
20.4.5 
EP2 Bulk-IN Transfer (Dual FIFOs) 
EP2 has two 64-byte FIFOs, but the user can perform data transmission and transmit data writes 
without being aware of this dual-FIFO configuration. However, one data write is performed for 
one FIFO. For example, even if both FIFOs are empty, it is not possible to perform EP2/PKTE at 
one time after consecutively writing 128 bytes of data. EP2/PKTE must be performed for each 64-
byte write. 
When performing bulk-IN transfer, as there is no valid data in the FIFOs on reception of the first 
IN token, a USBIFR0/EP2 TR interrupt is requested. With this interrupt, 1 is written to the 
USBIER0/EP2EMPTY bit, and the EP2 FIFO empty interrupt is enabled. At first, both EP2 FIFOs 
are empty, and so an EP2 FIFO empty interrupt is generated immediately. 
The data to be transmitted is written to the data register using this interrupt. After the first transmit 
data write for one FIFO, the other FIFO is empty, and so the next transmit data can be written to 
the other FIFO immediately. When both FIFOs are full, EP2EMPTY is cleared to 0. If at least one 
FIFO is empty, USBIFR0/EP2EMPTY is set to 1. When ACK is returned from the host after data 
transmission is completed, the FIFO used in the data transmission becomes empty. If the other 
FIFO contains valid transmit data at this time, transmission can be continued. 
When transmission of all data has been completed, write 0 to USBIER0/EP2EMPTY and disable 
interrupt requests.