Renesas HD6417641 用户手册

下载
页码 1036
Section 20   USB Function Module 
Rev. 4.00  Sep. 14, 2005  Page 782 of 982 
REJ09B0023-0400 
 
20.6.2 
Automatic Stall by USB Function Module 
When a stall setting is made with the Set Feature command, or in the event of a USB specification 
violation, the USB function module automatically sets the internal status bit for the relevant 
endpoint without regard to USBEPSTL register, and returns a stall handshake (1-1 in  
figure 20.14). 
Once an internal status bit is set, it remains set until cleared by a Clear Feature command from the 
host, without regard to USBEPSTL register. After a bit is cleared by the Clear Feature command, 
USBEPSTL is referenced (3-1 in figure 20.14). The USB function module continues to return a 
stall handshake while the internal status bit is set, since the internal status bit is set even if a 
transaction is executed for the corresponding endpoint (2-1 and 2-2 in figure 20.14). To clear a 
stall, therefore, the internal status bit must be cleared with a Clear Feature command (3-1 in figure 
20.14). If set by the application, USBEPSTL should also be cleared (2-1 in figure 20.14).