Renesas H8S/2111B 用户手册

下载
页码 582
Rev. 1.00, 05/04, page 176 of 544 
 
9.5.10 
Mask Signal Generation Timing 
When the ICRDMS bit in TOCR is set to 1 and the contents of OCRDM are other than H'0000, a 
signal that masks the ICRD input capture signal is generated. The mask signal is set by the input 
capture signal. The mask signal is cleared by the sum of the ICRD contents and twice the 
OCRDM contents, and an FRC compare-match. Figure 9.15 shows the timing of setting the mask 
signal. Figure 9.16 shows the timing of clearing the mask signal. 
Input capture 
signal
Input capture 
mask signal
φ
 
Figure 9.15   Timing of Input Capture Mask Signal Setting 
Compare-match 
signal
Input capture 
mask signal
ICRD + OCRDM 
× 2
N
FRC
N
N + 1
φ
 
Figure 9.16   Timing of Input Capture Mask Signal Clearing