Rev. 1.00, 05/04, page 268 of 544 
 
12.6.4 
Serial Data Reception (Clocked Synchronous Mode) 
Figure 12.18 shows an example of SCI operation for reception in clocked synchronous mode. In 
serial reception, the SCI operates as described below. 
1.  The SCI performs internal initialization in synchronization with a synchronization clock input 
or output, starts receiving data, and stores the receive data in RSR. 
2.  If an overrun error (when reception of the next data is completed while the RDRF flag is still 
set to 1) occurs, the ORER bit in SSR is set to 1. If the RIE bit in SCR is set to 1 at this time, 
an ERI interrupt request is generated. Receive data is not transferred to RDR. The RDRF flag 
remains to be set to 1. 
3.  If reception finishes successfully, the RDRF bit in SSR is set to 1, and receive data is 
transferred to RDR. If the RIE bit in SCR is set to 1 at this time, an RXI interrupt request is 
generated. Because the RXI interrupt routine reads the receive data transferred to RDR before 
reception of the next receive data has finished, continuous reception can be enabled. 
 
Bit 7
Serial data
Synchronization
clock
1 frame
RDRF
ORER
ERI interrupt request 
generated by overrun 
error
RXI interrupt 
request generated
RDR data read and 
RDRF flag cleared 
to 0 in RXI interrupt 
handling routine
RXI interrupt 
request 
generated
Bit 0
Bit 7
Bit 0
Bit 1
Bit 6
Bit 7
 
Figure 12.18   Example of SCI Receive Operation in Clocked Synchronous Mode 
Reception cannot be resumed while a receive error flag is set to 1. Accordingly, clear the ORER, 
FER, PER, and RDRF bits to 0 before resuming reception. Figure 12.19 shows a sample flowchart 
for serial data reception.