Renesas H8S/2111B 用户手册

下载
页码 582
Rev. 1.00, 05/04, page 427 of 544 
 
AV
CC
*
1
AN0 to AN5
AV
SS
Notes:  Values are reference values.
2.  Rin: Input impedance
1.
*
1
Rin*
2
100
Ω
0.1 µF
0.01 µF
10 µF
AV
ref
 
Figure 16.8   Example of Analog Input Protection Circuit 
20 pF
 To A/D converter
AN0 to AN5
  
10 k
Ω
Note:   *  Values are reference values.
 
Figure 16.9   Equivalent Circuit of Analog Input Pin  
16.7.6 Module 
Stop Mode Setting 
A/D converter operation can be enabled or disabled using the module stop control register. The 
initial setting is for A/D converter operation to be halted. Register access is enabled by canceling 
module stop mode. For details, refer to section 20, Power-Down Modes.