Renesas H8S/2111B 用户手册

下载
页码 582
Rev. 1.00, 05/04, page 457 of 544 
 
19.1.2 
External Clock Input Method 
Figure 19.4 shows a typical method of connecting an external clock signal. To leave the XTAL pin 
open, incidental capacitance should be 10 pF or less. 
To input an inverted clock to the XTAL pin, the external clock should be set to high in standby 
mode, subactive mode, subsleep mode, and watch mode. External clock input conditions are 
shown in table 19.3. The frequency of the external clock should be the same as that of the system 
clock (
φ). 
EXTAL
XTAL
External clock input
Open
(a) Example of external clock input when XTAL pin left open
EXTAL
XTAL
External clock input
(b) Example of external clock input when an inverted clock is input to XTAL pin
 
Figure 19.4   Example of External Clock Input