26.   Serial Sound Interface (SSI) Module 
Rev.1.00  Jan. 10, 2008  Page 1327 of 1658 
REJ09B0261-0100 
 
26.4.4
 
Operation Modes 
There are three modes of operation: configuration, enabled and disabled. Figure 26.20 shows the 
transition diagram between these operation modes. 
EN = 1
(IDST = 0)
EN = 0
(IDST = 0)
EN = 0
(IDST = 1)
Module
configration
(after reset)
Module
enabled
(normal tx/rx)
Module
disabled
(waiting until
bus inactive)
Power-on reset
Manual reset
 
Figure 26.20   Transition Diagram between Operation Modes 
(1)
  Configuration Mode 
This mode is entered after the module is released from reset. All required settings in the control 
register should be defined in this mode, before the SSI module is enabled by setting the EN bit.  
Setting the EN bit causes the SSI module to enter the module enabled mode. 
(2)
  Module Enabled Mode: 
Operation of the module in this mode depends on the selected operating mode. For details, see 
section 26.4.5, Transmit Operation and section 26.4.6, Receive Operation.