19.   Display Unit (DU) 
Rev.1.00  Jan. 10, 2008  Page 959 of 1658 
REJ09B0261-0100 
 
19.5.2
 
CSYNC 
When in master mode, a CSYNC (composite sync) signal is output. EQWR is used to set the low-
level pulse width of the CSYNC equal pulse. SPWR is used to set the low-level pulse width of the 
CSYNC separation pulse. 
The CSYNC waveform is selected using the CSY bit in DSMR. 
HSW
HSYNC 
VSYNC 
CSYNC 
(CSY = 00) 
EQW 
(CSY = 10) 
(CSY = 11) 
HC 
SPW 
1/2HC 
When HC is odd, it is rounded to an even value.
Equivalent pulse: 
2.5 rasters
Separation pulse: 
2.5 rasters
Equivalent pulse:
2.5 rasters
Equivalent pulse: 
3 rasters
Separation pulse: 
3 rasters 
Equivalent pulse: 
3 rasters
 
Figure 19.14   CSYNC Timing Chart (Non-Interlaced Mode, First Half of Interlace Frame)