Renesas M16C FAMILY 用户手册

下载
页码 103
5 Using the KD 
5.2 KD Limitations 
5.2.1 Limitations on Special Page Vector 
A Monitor Program uses several Special Page Vectors. Therefore, the Special page 
Vector which can be used in the User Program is limited as Special Page Vector 
Number shown in the following table. 
When updating the version of the Monitor Program (or Firmware), the Special Page 
Vector which can be used in the User Program may be modified. 
 
Table 5-1 Specail Page Vector Limitations 
Group 
Available Special Page Vector Number 
M16C/10 
#127 to #24 
M16C/1N 
#238 to #24 
M16C/24 
#234 to #24 
M16C/26 
#205 to #24 
M16C/26A, 28, 29 
#199 to #24 
M16C/62A (M) 
M16C/6N (6NA, 6NB) 
#234 to #24 
M16C/62P 
M16C/6N (6N4, 6N5) 
#200 to #24 
M16C/62N (M3062GF8N) 
#237 to #24 
M16C/80 
#196 to #24 
M32C/83 
#182 to #24 
M32C/84, 85, 86, 87 
#164 to #24 
Note: The contents in this Table are applied to the following KD30/KD3083. 
- KD30 Ver.4.10 Release 1 (Firmware version: V.8.00) 
- KD3083 Ver.3.30 Release 1 (Frimware version: V.8.00) 
 
 
 
 
59