I N S T A L L A T I O N   A N D   S E T U P
System Timing
350-7951
Quadra User’s Guide
20
. .
 . 
.
Quadra can be used with both standard and non-standard display devices.  You 
can allow Quadra to automatically “learn” the display’s timing parameters, or 
you can enter your own.  Internally, Quadra keeps an “
that contains both factory-defined and user-defined timing values.
The first 99 entries in the Factory Timing List are reserved for factory 
defined entries.  
Entries from 100 to 160 are reserved for user-defined values.  
The “user entry” feature is helpful for storing non-standard timing 
information, or special applications where a preset timing parameter 
needs to be adjusted — and then stored in a register.  In some cases, 
you may also need to create your own custom timing parameters.
Quadra performs its timing functions in the following way:
When you connect a display to one of Quadra’s outputs, Quadra 
automatically measures the display’s timing parameters.  
Quadra then searches the “user entry” section of the Factory Timing 
List
.  If it finds a match (for example, one that you have previously 
stored), it selects and loads those parameters.
If Quadra does not find a match in the “user entry” section, it searches 
through all factory defined entries and loads the closest match.
If you want to manually enter your own parameter to more closely 
match those of the selected display monitor, the “
” procedure enable you to do so, and store 
those settings in a memory register. 
. . . . . . . . . 
OUTPUT TIMING
The Output Timing procedure enables you to match a channel’s output signal 
to the graphic display device that is attached to that channel.  Quadra generates 
a wide range of preset VESA-compliant output formats, and also enables users 
to define custom values.    
The overall procedure has four parts:
Learn the characteristics of the display device(s) that are connected to 
Quadra’s output channels.
For the first output channel, load the required output format using the 
” function.
Use your display’s controls to center and size the image.
Repeat the procedure for all remaining output channels and their 
associated displays.
A list of common device signal types that Quadra supports can be found in the 
Important
If you choose to manually enter timing parameters, the 
output timing procedure should be performed first, 
followed by the input timing procedure.  This sequence 
should be repeated for each of Quadra’s four channels.