O P E R A T I O N S
Understanding Auto Sync
350-7951
Quadra User’s Guide
35
. .
 . 
.
Once a close match is found for each RGB input, Quadra tries to lock to it — or 
continues down the list until a “lock” is achieved.  
LOADING INPUT
. . . . . . . . . 
TIMING VALUES
To load a different set of parameters or “create” your own, Auto Sync can be 
disabled — and you can force Quadra to load a custom set of parameters.
Use the following steps to load timing values:
1.
To discover which set of timing parameters are currently loaded, query 
the 
 command for a selected input.  Type:
INTM <input #> 
Enter
The display shows the input name and all the various parameters.  If 
the name “Auto_1” appears, this indicates the active register for 
automatic settings when Auto Sync is enabled.  (There are four 
Auto_1” registers, one for each Quadra input.)
2. 
Request help text for th
 command.  Type:
H INLOAD 
Enter
This action displays the command’s parameters and variables.
Figure 3-8.  
Help Text — Input Load Command
3. 
Show the timing list.  Type:
TMLIST 
Enter
4. 
Review the Factory Timing List in detail, and note the timing 
parameters that most closely match the specifications of your input.
5. 
Turn off Auto Sync for the selected input.  Type:
INAS <input #> OFF 
Enter
6. 
Load the desired timing parameters for the selected input.  Type:
INLOAD <input #> <register #> 
Enter
7. 
Verify that the parameters are loaded by querying the command and 
the input.  Type:
INTM <input #> 
Enter
8. 
Repeat from step 1 to load custom timings for additional inputs.