III - Hardware Configuration 
Before installing the module in a chassis, there are two features that must be selected 
using the DIP switches.  These selections are: 
•  Enable or disable management on each port  
(DIP switches 1, 2, and 3) 
•  Configure the module as a standalone, a host, or a remote  
(DIP switches 7 and 8) 
DIP Switch Settings 
Before installing the iMcV-Giga-FiberLinX-II, use the DIP switches to set the 
hardware-configurable features.  The DIP switches are located on switch SW1 on the 
iMcV-Giga-FiberLinX-II card.  Refer to the diagram and table for switch settings and 
available features. 
 
Switch 
Function 
Default Setting 
Management on EXT MGMT port 
ON 
Management on DATA port
 
OFF 
Management on OPTICS or 
UPLINK port 
OFF 
Factory use - Do not change --- 
Factory use - Do not change 
--- 
Factory use - Do not change 
--- 
Remote Module 
OFF 
Host Module 
OFF 
Factory use - Do not change 
--- 
Factory use - Do not change 
--- 
Host/Remote and Standalone Units 
The iMcV-Giga-FiberLinX-II can be used as a Host, Remote, or Standalone unit.  
Refer to the Application Examples section for examples. 
When two iMcV-Giga-FiberLinX-II units are used as a pair, configure one as a Host 
unit (DIP switch 8 = ON) and the other as a Remote unit (DIP switch 7 = ON).  As a 
host unit, the iMcV-Giga-FiberLinX-II requests management information from the 
attached remote unit.  It then displays that information, along with its own, when