IMC Networks iMcV-Giga-FiberLinX-II 用户手册

下载
页码 60
 
11 
FiberAlert 
FiberAlert minimizes the problems associated with the loss of one strand of fiber. 
Normally when a single strand of fiber is lost, the transmitting side of the connection 
is unaware that there is a fault.  FiberAlert returns faults back on the fiber they came 
in on. 
Using LinkLoss and FiberAlert 
In a typical central site to remote site media conversion, it is recommended that you 
enable the LinkLoss and FiberAlert features as indicated in the following:   
FiberAlert and LinkLoss 
Feature 
Enabled 
Fault Location 
Port affected 
FiberAlert 
Remote Side Only 
Fiber 
Fiber 
TX LinkLoss 
Remote Side (or both) 
Twisted Pair 
Fiber 
FX LinkLoss 
Host Side (or both) 
Fiber 
Twisted Pair 
**  WARNING  ** 
Do not enable FiberAlert on both modules when using iMcV-Giga-FiberLinX-II 
in pairs.  This will cause them to lock up when a fault occurs on the fiber.  
Only enable FiberAlert on the remote module
Link Fault Pass-Through 
Link Fault Pass-Through (LFPT) is a troubleshooting feature that combines TX and FX 
LinkLoss from both the local and remote iMcV-Giga-FiberLinX-II modules.  LFPT is 
enabled by turning on both FX and TX LinkLoss on both modules.  This feature allows 
either end of the conversion to detect a link fault occurring at the other end of the 
media conversion chain: 
•  A cable fault occurs on the remote twisted pair. 
•  TX LinkLoss detects the fault and disables the OPTICS (or UPLINK) port. 
•  FX LinkLoss detects the fiber loss and disables the DATA port.  
The link fault is passed through the media conversion and is observed at each end.  It 
acts just like it would if the devices were directly connected. 
NOTE 
FiberAlert can also be added to the remote side of the pair to further assist in 
locating a fault.