25 
must enter Y in the Tags column for both the Optics row and Data row.  Enter up to 
32 VLAN IDs in the Data VLANs fields, plus one for SNMP. 
 
Management VLAN and EXT MGMT Tag 
This selection is available for all VLAN modes except for the default mode.  Configure 
a VLAN ID for management traffic by entering an ID in the VLAN IDs – Saved column 
of the SNMP row (in this example, 200).   
The EXT MGMT tag parameter provides the option of adding the defined 
Management VLAN ID to all untagged traffic entering the EXT MGMT port (EXT 
Mgmt Tag = N) or restricting the EXT MGMT port to pass only traffic bearing this 
VLAN ID (EXT Mgmt Tag = Y) 
 
Saved VLAN Values <Active after reboot>. Current VLAN Values <Active now>.
 
  Tags 
            VLAN IDs          Priorities   
        Current   Saved    Current   Saved 
 Ports                                              Data VLANs are used only 
 
 Optics  [0   ]   [
0
   ]    [0  ]    [
0
  ]   [ 
Y
 ]  if Tags are enabled on both
e Optics and Data Ports. 
 Data    [0   ]   [
0
   ]    [0  ]    [
0
  ]   [ 
Y
 ]  th
 Management VLAN                         EXT Mgmt Tag 
NMP    [0   ]   [
0
   ]    [0  ]    [
0
  ]   [ 
N
 ]    
 S
 
 Data VLANs  <Optics <----> Data> 
 VLAN  1 [0   ]   [
900
 ]  VLAN 12 [0   ]   [
911
 ]   VLAN 23 [0   ]   [
922
 ] 
 VLAN  2 [0   ]   [
901
 ]  VLAN 13 [0   ]   [
912
 ]   VLAN 24 [0   ]   [
923
 ] 
 VLAN  3 [0   ]   [
902
 ]  VLAN 14 [0   ]   [
913
 ]   VLAN 25 [0   ]   [
924
 ] 
 VLAN  4 [0   ]   [
903
 ]  VLAN 15 [0   ]   [
914
 ]   VLAN 26 [0   ]   [
925
 ] 
 VLAN  5 [0   ]   [
904
 ]  VLAN 16 [0   ]   [
915
 ]   VLAN 27 [0   ]   [
926
 ] 
 VLAN  6 [0   ]   [
905
 ]  VLAN 17 [0   ]   [
916
 ]   VLAN 28 [0   ]   [
927
 ] 
 VLAN  7 [0   ]   [
906
 ]  VLAN 18 [0   ]   [
917
 ]   VLAN 29 [0   ]   [
928
 ] 
 VLAN  8 [0   ]   [
907
 ]  VLAN 19 [0   ]   [
918
 ]   VLAN 30 [0   ]   [
909
 ] 
 VLAN  9 [0   ]   [
908
 ]  VLAN 20 [0   ]   [
919
 ]   VLAN 31 [0   ]   [
930
 ] 
  VLAN 32 [0   ]   [
931
 ] 
 VLAN 10 [0   ]   [
909
 ]  VLAN 21 [0   ]   [
920
 ] 
 VLAN 11 [0   ]   [
910
 ]  VLAN 22 [0   ]   [
921
 ] 
7. 
Valid VLAN IDs are between 1 and 4094. Valid priorities are between 0 and 
Type S or F3 to save the changes. Type Q or F4 to quit and cancel changes.
Saved VLAN Values <Active after reboot>. Current VLAN Values <Active now>.
 
  Tags 
            VLAN IDs          Priorities   
        Current   Saved    Current   Saved 
 Ports                                              Data VLANs are used onl
 Optics  [0   ]   [
  ]    [0  ]    [
0
  ]   [ 
Y
 ]  if Tags are enabled on 
both 
e Optics and Data Ports. 
 Data    [13  ]   [13  ]    [0  ]    [
0
  ]   [ 
Y
 ]  th
 
t
 
 Management VLAN                         EXT Mgm  Tag
 SNMP    [0   ]   [
200
 ]    [0  ]    [
0
 ]   [ 
N
]   
***WARNING*** 
If the device is currently managed on any port other than the EXT MGMT 
port, do not leave the Management Tag field defined as zero (0).  This will 
disable management traffic on the iMcV-Giga-FiberLinX-II.  You must enter a 
VLAN ID between 1 and 4094 (excluding the VLAN IDs used for the Port 
VLAN or for the Data VLANs). 
Unit Configurationunit 
The iMcV-Giga-FiberLinX-II allows you to view unit status as well as configure some 
unit features by using a serial connection or a Telnet session.  In the Main