IBM EM78M611E 用户手册

下载
页码 44
EM78M611E
 
Universal Serial Bus Series Microcontroller
 
 
12 
•••
 
Product Specification (V1.1) 11.22.2006
 
 
(This specification is subject to change without further notice) 
 
R3 [2] Zero flag. It will be set to 1 when the result of an arithmetic or logic operation is 
zero.  
R3 [3] Power down flag. It will be set to 1 during Power-on phase or by “WDTC” 
command and cleared when the MCU enters into Power down mode.  It remains 
in its previous state after a Watchdog Reset. 
 
0
: Power down 
 
1
: Power-on 
R3 [4] Time-out flag.  It will be set to 1 during Power-on phase or by “WDTC” 
command.  It is reset to 0 by WDT time-out.  
 
0
: Watchdog timer overflow occurs 
 
1
: No Watchdog timer overflow  
The various states of Power down flag and Time-out flag at different conditions are 
shown below: 
Condition 





*

Power-on reset 
WDTC instruction 
WDT time-out 
Power down mode 
Wake up caused by port change during Power down mode 
*
P
: Previous status before WDT reset 
R3 [5-7]  Page selection bits. These three bits are used to select the program memory 
page. 
PS2 
PS1 
PS0 
Program Memory Page [Address] 
Page 0 [0000-03FF] 
Page 1 [0400-07FF] 
Page 2 [0800-0BFF] 
Page 3 [0C00-0FFF] 
Page 4 [1000-13FF] 
Page 5 [1400-17FF]