IBM 4.6.x 用户手册

下载
页码 140
path="situation/situationType/situationQualifier"
          
required="true"
          
permittedValue="START_INITIATED"
          
permittedValue="RESTART_INITIATED"
          
permittedValue="START_COMPLETED"
 
/>
 
</eventDefinition>
 
XML
 
format
 
for
 
stop
 
adapter
 
metadata
 
The
 
metadata
 
for
 
“stop
 
adapter”
 
is
 
the
 
same
 
as
 
that
 
for
 
“start
 
adapter”
 
with
 
the
 
following
 
exceptions:
 
v
   
The
 
default
 
value
 
for
 
the
 
categoryName
 
property
 
is
 
StopSituation
:
 
<property
 
name="categoryName="
  
//Comment:
 
Specifies
 
the
 
type
  
of
 
situation
 
for
 
the
 
event
               
path="situation/categoryName"
               
required="true"
               
defaultValue="StopSituation"/>
 
v
   
The
 
permitted
 
values
 
for
 
the
 
situationQualifier
 
property
 
differ
 
and
 
are
 
as
 
follows
 
for
 
“stop
 
adapter”:
 
<property
 
name="situationQualifier"
  
//Comment:
 
Specifies
 
the
 
situation
 
qualifiers
 
for
 
this
 
event
            
path="situation/situationType/situationQualifier"
            
required="true"
            
permittedValue="STOP_INITIATED"
            
permittedValue="ABORT_INITIATED"
            
permittedValue="PAUSE_INITIATED"
            
permittedValue="STOP_COMPLETED"
  
/>
 
XML
 
format
 
for
 
“timeout
 
adapter”
 
metadata
 
The
 
metadata
 
for
 
“timeout
 
adapter”
 
is
 
the
 
same
 
as
 
that
 
for
 
“start
 
adapter”
 
and
 
“stop
 
adapter”
 
with
 
the
 
following
 
exceptions:
 
v
   
The
 
default
 
value
 
for
 
the
 
categoryName
 
property
 
is
 
ConnectSituation
:
 
<property
 
name="categoryName="
  
//Comment:
 
Specifies
 
the
 
type
  
of
 
situation
 
for
 
the
 
event
               
path="situation/categoryName"
               
required="true"
               
defaultValue="ConnectSituation"/>
 
v
   
The
 
permitted
 
values
 
for
 
the
 
situationQualifier
 
property
 
differ
 
and
 
are
 
as
 
follows
 
for
 
“timeout
 
adapter”:
 
<property
 
name="situationQualifier"
  
//Comment:
 
Specifies
  
the
 
situation
 
qualifiers
 
for
 
this
 
event
            
path="situation/situationType/situationQualifier"
            
required="true"
            
permittedValue="IN_USE"
            
permittedValue="FREED"
            
permittedValue="CLOSED"
            
permittedValue="AVAILABLE"
  
/>
   
116
 
Adapter
 
for
 
Siebel
 
eBusiness
 
Applications
 
User
 