2 - 8   O v e r v i e w  
SG  20 00  Ins tal la tion  and  O pera tion  M anua l  
 
To assess fiber link status, the optical-power monitor circuit is active at all times (even when the 
receiver is disabled). An integrated optical bulkhead connector and module link status indicators 
enhance fiber management and reduce troubleshooting time. The receiver module is fully compatible 
with the status monitor transponder for remote monitoring of key module and link performance 
parameters. 
Several plug-in boards are available to configure the SG 2000 lid board for single, redundant, or 
narrowcast receiver arrangements. A low-noise pre-amplifier hybrid amplifies the signal to a level 
suitable for connection to the RF chassis. 
An SG2-FRB flatness board, at the input to the RF chassis, compensates for hybrid and accessory 
response signatures. A variable attenuator circuit enables fine adjustment of the output level, and is 
driven either by the standard thermal control unit (TCU) or optional ADU pilot automatic gain 
control (AGC) module to compensate for temperature and input level variations. 
The MDR-*/* circuit board provides a fixed linear equalizer for either 750 MHz or 870 MHz. This 
equalizer comes in numerous values to support various levels of output tilt. The MDR board also 
compensates for the low frequency roll-off inherent in plug-in diplexers. 
A driver-hybrid amplifies the signal to a sufficiently high level to feed up to four power-doubling 
output stages. These output hybrids can be either conventional silicon or premium gallium arsenide 
types for even higher station output at low distortion. Plug-in facilities are available ahead of each 
output stage for individual equalizer boards. These can be installed to customize the tilt for the 
various ports. At one output, a minus 16 dB directional coupler provides signal to the optional ADU 
and status-monitor modules. This signal is used only when either or both of these options is installed. 
It is not necessary to terminate the coupler output when neither option is present. 
Minus 20 dB directional test points are available at various points in the signal paths of the node. 
Because these test points are 75-ohm source impedance, special test probes are not required. 
Model JXP-* attenuator pads are used for adjusting signal levels within the signal path. The unit is 
shipped with JXP-ZX versions installed.