B e n c h S e t u p
3 - 7
S G 2 0 0 0 I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l
Single Power Supply or Commonly Powered Redundant Supplies
To activate a single power supply or commonly powered redundant supplies, place jumper JP1
(illustrated in Figure 3-1) on the SG2-LIDB in the vertical position (strand-mount installation).
Figure 3-6 illustrates this position. Power supplies #1 and #2 are both connected to the primary ac
power feed.
F i g u r e 3 - 6
J P1 c o m m o n - p o w e r e d s i n g l e o r r e d u n d a n t p o w e r c o n f i g u r a t i o n
Secondary AC
Primary AC
Power supply #2
Power supply #1
JP1
Individually Powered Supplies
To activate split ac powering of the node, place jumper JP1 on the SG2-LIDB in the horizontal
position (strand-mount installation). Figure 3-7 illustrates this position. Fuse jumper F7 must also be
removed. The primary ac power feed now connects to power supply #l and an independent
secondary ac source is connected to power supply #2. This configuration implies that the primary ac
power source originates from port
IN
, port 1 or port 2. The secondary ac power source originates
from port
OUT
or port 3. For this configuration the optional interconnect cable (SG2-SIC) must be
installed between the lid board and the RF chassis.
F i g u r e 3 - 7
J P1 s p l i t - p o w e r e d r e d u n d a n t p o w e r s u p p l y c o n f i g u r a t i o n
Secondary AC
Primary AC
Power supply #2
Power supply #1
JP1
Other power configurations are possible, but not recommended.
C A U T I O N !
Take extreme care so that you do not directly connect primary and secondary power
sources when implementing other configurations.