SG  20 00  Ins tal la tion  and  O pera tion  M anua l 
SG 2000 Optical Modules 
The optical modules available for the SG 2000 include: 
!  SG2-LR — forward path optical receiver 
!  SG2-EIFPT — isolated Fabry-Perot return transmitter 
!  SG2-IFPT — isolated Fabry-Perot return transmitter 
!  SG2-FPT — non-isolated Fabry-Perot return transmitter 
!  SG2-DFBT and SG2-DFBT/3 — isolated DFB return transmitters 
!  DS-SG2-DRT/A and DS-SG2-DRT-2X/A — digital return transmitters 
Designed specifically for use in the SG 2000 node platform, the modules combine high performance 
and easy maintenance. 
Installing SG 2000 Optical Modules 
The design of the SG 2000 optical modules enable you to install them while the node is in service. 
To install an optical module: 
Determine the proper slot for the module by referring to the Forward Path RF Configuration or 
the Return Path RF Configuration information in the beginning of this section. Position the 
module in the appropriate slot and press gently on the casting until it is fully seated. Tighten the 
two mounting bolts to secure the module in the SG 2000 lid. 
Remove the dust covers from the service cable connector and the module’s optical connector. 
Carefully clean the optical connector using a suitable optical cleaning kit. 
Connect the service cable to the module’s optical connector. 
If necessary, check the optical power levels. Check and align the RF levels in accordance with 
system requirements and procedures. 
Removing SG 2000 Optical Modules 
The SG 2000 optical modules design enables you to remove them while the node is in service. 
C A U T I O N !  
 
The module surfaces may be hot. Allocate sufficient time for the module to cool before 
handling. 
 
 
To remove an optical module: 
Disconnect the service cable from the optical connector assembly on the module. Place dust 
covers on the service cable connector and the modules optical-connector assembly. 
Loosen the two mounting bolts that secure the optical module in the SG 2000 lid. 
Pull the module from the SG 2000 lid using the wire handle on top of the module.