Motorola SG 2000 用户手册

下载
页码 105
   
O p e r a t i o n  
5 - 2 3  
 
SG  20 00  Ins tal la tion  and  O pera tion  M anua l 
Table 5-9 provides information on the user-related features of the DS-SG2-DRT-2X/A: 
T a b l e   5 - 9    
D S - S G 2 - D R T - 2 X / A  f e a t u r e s  
Feature Desc ription 
Test point A and B 
These test points enable monitoring of the RF level at the input to 
the A/D. It measures 
20 dB from the A/D input level. 
Input A and B 
 
 
 
 
 
I
ncrement attenuator 
 setting 
 
 
 Decrement 
attenuator 
 setting 
 
 
 Change 
increment/ 
 
 decrement 
direction 
 
 
 
 
 
Restore factory default 
 setting 
The transmitter has a digitally controlled attenuator that adjusts for 
varying input levels. These push-buttons are input level-control 
adjustments that provide 
+
2 to 
13 dB of adjustment from an input 
level of 15 dBmV. No action is taken if both buttons are pressed. 
Short press (0.1 to 1.5 seconds). The status LED indication is 
green with a short OFF blink (0.25 sec.) when the button is 
released. A short red blink occurs if the increment attempts to go 
past the maximum. 
Short press (0.1 to 1.5 seconds). The status LED indication is 
green with a short yellow blink (0.25 sec.) when the button is 
released. A short red blink occurs if the decrement attempts to go 
past the minimum. 
Medium press (1.5 to 5.0 seconds). The status LED is OFF after 
1.5 seconds when in the increment direction, and yellow when in 
the decrement direction. The LED is restored to its green or alarm 
state when the button is released. No increment or decrement 
occurs. 
Long press (5.0 seconds or longer). The status LED flashes green 
and yellow rapidly until the button is released. After five seconds of 
flashing, the factory defaults are restored. 
Status 
This tri-color LED is green if all parameters are within specification. 
A series of red flashes indicate an alarm condition. The number of 
red flashes indicate the parameter that is outside the specification. 
Alarms 
 No 
alarm 
 
Over temperature (> 
++++
85°C)
 Low 
++++
24 Vdc (< 
++++
18 Vdc) 
 Low 
++++
5 Vdc (< 
++++
4.5 Vdc) 
 Low 
++++
2.5 Vdc (< 
++++
2.2 Vdc) 
 
Laser bias/optical power  
 
out of spec. 
Status LED indication: 
Steady green 
Long red, one red flash (repeating) 
Long red, two red flashes (repeating) 
Long red, three red flashes (repeating) 
Long red, five red flashes (repeating) 
Long red, six red flashes (repeating) 
RF input B 
This input is the second RF return signal that is obtained from the 
adjacent transmitter connector through a provided cable. The cable 
is illustrated in Figure 5-27. 
It is recommended that you restore the factory default settings before you set up the node levels. This 
procedure places the transmitter input level 2 dB below maximum.