In g re ss   Con trol 
The SG 2000 platform incorporates electronic ingress control switching enabling operators to choose 
one of three options for troubleshooting noise sources. A maximum of four switches, (one ingress 
switch per RF port) can populate the RF amplifier. Figure 3-2 illustrates their location on the RF 
chassis. 
Ingress switches are controlled in one of two ways: (1) remotely — through the optional on-board 
LL-SG2 transponder in communication with the status monitoring system or; (2) locally — using the 
manual control board (MCB). 
The three states of the switch and their functions include: 
State Desc ription 
Off 
Effectively isolates the contaminated leg by adding a minimum of 40 dB attenuation. 
–6 dB  
Typically initiated at the headend, it provides –6 dB additional attenuation to the return 
signal. This is useful in diagnosing noise presence without interfering with normal 
service. 
On 
Completes the return path without alteration to the return signal.