2-6 Installing the Modem
Installi
ng
the M
odem
Figure 2-3. 3261/3266 Modem Rear Panel Layout
Electrical Interfaces—EIA/TIA-232 and ITU-TS V.35
Caution
Ensure that the electrical interfaces of the equipment you connect 
to the modem are compatible. Incompatible interfaces may 
seriously damage the modem. Motorola makes no guarantee of the 
equipment’s integrity if you do not ensure that compatible inter-
faces are used. If your DTE has a different interface, you will need 
an external converter cable. 
326X Series Modems have an EIA/TIA-232/EIA/TIA-562 electrical interface for 
connection to external equipment. For compatibility with DTEs that have a V.35 
interface, the V.34-SDC Modem is also available with the optional ITU-TS V.35 
Recommendation electrical interface.
The rear-panel DTE port is configured at the factory for either interface. Both 
interfaces are not available in a unit.
 Regardless of the interface, external DTEs are 
connected through the modem’s rear-panel DTE port.
NOTE: When operating with the V.35 interface, DIP switch S1 must be set to the off 
(up) position (see Figure 2-2 or 2-3).
To purchase a compatible cable, consult Appendix B.
Operating at V.34 DTE Rates
To operate V.34 or V.34-SDC modems at DTE rates greater than 19.2 kbps, you must 
use cables that can handle the higher data rates. Refer to Appendix B for instructions 
on determining the correct cables to use.
PHONE
DIAL
LINE
OUT
IN
NC
DTE
1 ON 6
1 2 3 4 5 6 
1
2 3
4
5 6
LEASE
LINE
Factory Preset 6-Position 
DIPs are Off (Up)