MRV Communications TS700/155 用户手册

下载
页码 77
M R V   C o m m u n i c a t i o n s ,   I n c .   –   I n s t a l l a t i o n   M a n u a l  
27 
Table 6:  DIP Switch Setting for TereScope 
TS700/155 TS800/155 
Function 
OFF ON OFF  ON 
Fast Ethernet 
4,5 – 
1,2,3,4 
– 
ATM/OC3/STM1: 155 Mbps 
– 
4,5 
2,3,4 
SMPTE 143 Mbps 
– 3,4 
1,2 
E3:34.368 Mbps 
4
 
1,2,4 3 
T3:44.736 4 
5
 
2,4 1,3 
OC1/STMO:51.840 Mbps 
– 
1,4 2,3 
Customized 1 
– 
4 1,2,3 
Customized 2 
– 
1,3,4 2 
Open Protocol 
– 
1,2,3 4 
 
Mode Select DIP switch toggle 
Set DIP switch toggles 1 and 2 to the OFF position for normal operation. (In 
TS800/155 and TS800/155-F set the DS2 1, 2, 3 and 4 toggles to OFF position) 
 
2 – TS700/100 (Fast ethernet) 
Compatibility 
 
 
Peripheral equipment 
Check the operation of the peripheral equipment connected with cables (see 
Configuration 1 below). 
 
Interfaces 
Check the specifications compatibility (type, data rate) between the TereScope and 
the peripheral equipment interfaces. 
 
Test equipment 
 
Chose an appropriate Bit Error Rate (BER) tester for checking the physical link 
quality. A portable one is preferable since it is more convenient for use in the field. 
 
A ping test or a file transfer between two workstations - connected to the 
networking equipment - is useful and easy to implement for testing the 
performance of the whole configuration. 
Setup 
DIP Switch 
Set DIP switch toggles 1 and 2 to the OFF position for normal operation. 
Set DIP switch toggle 4 for the speed. Usually with Cisco Switches set the TS to 
Auto-negociation mode.