Motorola MPC5200 用户手册

下载
页码 28
M5200E-6
KADAK
MPC5200 FEC Device Driver
MPC5200 FEC Ethernet
Device Driver Data Sheet 
(continued)
Configuring the MPC5200 FEC Ethernet Device Driver
Use the 
KwikNet
 Configuration Manager to edit your Network Parameter File to include
this Ethernet device driver.  Assume that you require the following configuration for use
on the Motorola Lite5200 Evaluation Board.
MPC5200 FEC is to be used operating at 10Mbps.
Caching must be accommodated.
The Ethernet link must operate in half duplex mode.
PHY device wiring mode is 18-wire (MII).
The controller is to be assigned Ethernet address 
0x00049F000A97
.
KwikNet
 IRQ identifier 71 (
0x47
) identifies the BestComm Ethernet RX task as the
interrupt source.
KwikNet
 IRQ identifier 41 (
0x29
) identifies FEC channel 0 as the interrupt source.
2 transmit buffers and 8 receive buffers are required.
Enter the following five device driver parameters:
Parameter #1:
0x00040000
Parameter #2:
0x9F000A97
Parameter #3:
0
Parameter #4:
0x00470029
Parameter #5:
0x00020008
Generate your 
KwikNet
 Library Make File and use it to build your 
KwikNet
 Library.
Compile the 
KwikNet
 board driver module 
KN_BOARD.C
.
Create the 
KwikNet
 MPC5200 BestComm Library 
KN5200E.A
 from the compiled object
modules for the device driver module 
M5200E.C
, the pin assignment module
M5200EBS.C
, the BestComm support module 
KN5200BC.C
 and the BestComm API and
microcode source files.  Follow the instructions provided in Chapter 5 of the 
KwikNet
MPC5200 FEC Device Driver User's Guide.
Revise your 
KwikNet
 application link specification to include the board driver object
module 
KN_BOARD.O
 along with your application modules.  Link library module
KN5200E.A
 after the 
KwikNet
 PPC
32
 Library 
KN383IP.A
 or the 
KwikNet
 Porting Kit
Library 
KN713IP.A
.