MRV Communications TS700/100 用户手册

下载
页码 77
M R V   C o m m u n i c a t i o n s ,   I n c .   –   I n s t a l l a t i o n   M a n u a l  
5 
 
B.  TS800/155 Standard Model 
The TS800/155 supports most of the prevalent protocols in the 34-155 Mbps 
range.  Support for a special protocol, which is not on the list, can be ordered after 
coordination with the factory. This model can be used for Open Protocol 
applications which ensures complete transparency (including all data in the 
range of 1-155 Mbps.)
  In this case, a maximum 2 dB of the power budget is lost.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Back Panel Description 
 
Table 3:  TS800/155 Standard Model Back Panel Controls, Interfaces, and Indicators
 
Power
 
Power source Terminal Block (Main or UPS). 
AC power supply (100 to 240 Vac) or DC power 
supply (24 to 60 Vdc) 
Fiber optic 
 
Fiber Optic interface for connection to the 
peripheral equipment. The standard interface is MM 
1310nm SC connector; other interfaces are available 
upon request. 
In model TS800/155-F with the fusion option, there 
are two fiberoptic interface ports for connection to 
the Fusion system; one primary and the other 
redundant. 
Remote monitor 
Connection to the RSM. (The RSM has to be 
ordered separately) 
Connectors
 
Management 
 
Connection to 10Base-T SNMP management 
interface.  Pins 1,2: TX and 3,6 RX. 
Pins (4,5) and (7,8) of this connector can be used 
for dry contact purposes, for Airlink flag and F/O 
flag alarms respectively
 
Figure 1.3: TS800/155 Standard Model Panel Schematic