MRV Communications TS700/100 用户手册

下载
页码 77
M R V   C o m m u n i c a t i o n s ,   I n c .   –   I n s t a l l a t i o n   M a n u a l  
28 
3 – TS700/G 
Compatibility 
 
 
Peripheral equipment 
Check the operation of the peripheral equipment connected with cables (see 
Configuration 1 below). 
 
Interfaces 
Check the specifications compatibility (type, data rate) between the TereScope and 
the peripheral equipment interfaces. 
 
Test equipment 
 
Chose an appropriate Bit Error Rate (BER) tester for checking the physical link 
quality. A portable one is preferable since it is more convenient for use in the field. 
 
A ping test or a file transfer between two workstations - connected to the 
networking equipment - is useful and easy to implement for testing the 
performance of the whole configuration. 
Setup 
DIP Switch 
Set DIP switch 1 to OFF (attenuated transmitter) in order to enable short range 
operation with minimal extra attenuation.  Set DIP switch 4 to appropriate 
protocol – ON for Gigabit Ethernet, OFF for FiberChannel. 
Bench test 
To learn more about TereScope Bench Test, please refer to Appendix E.
 
 
Configuration 1: (Applicable to all models) 
Peripheral/Testing
Equipment
RX
TX
Peripheral/Testing
Equipment
TX
RX
Cables
 
 
Configuration 2: (Applicable to all models) 
BER Tester
TX
RX
UWIN
RX
TX
UWIN
RX
TX
IR link
 
Peripheral equipment 
and cable testing 
1-way Airlink  
BER test 
TS
TS