页码 86
Manual No. 775012
D-1
Appendix D
Enclosure Management
Introduction
Mylex’s DAC960PG/PJ Disk Array Controllers support the industry 
standard enclosure management protocol SCSI Accessed Fault-Tolerant 
Enclosures
 (SAF-TE). This feature allows the host to monitor drive 
enclosures and detect certain faults or operating environment conditions. 
The host can make a decision to shut down the system or issue a warning 
based on the type of fault detected.
SAF-TE
The SAF-TE protocol follows a specification jointly worked out by nStor 
Corporation and Intel Corporation. Enclosures that are compliant with this 
protocol are known as SCSI Accessed Fault-Tolerant Enclosures (SAF-TE). 
The protocol is compatible with standard SCSI buses and cabling.
The SAF-TE interface standard’s objective is to provide a non-proprietary 
means of allowing third-party disks and controllers to be automatically 
integrated with peripheral enclosures that support:
• Status Signals (LEDs, audible alarms, LCDs, etc.)
• Hot swapping of drives
• Monitoring of fans, power supplies, and enclosure temperature
SCSI is the underlying transport mechanism for communicating enclosure 
information. All standard SCSI host adapters will work. There is no need to 
consider reserved signals or special cabling.
The SAF-TE interface can be implemented as a SCSI target that uses a SCSI 
port and an 8-bit microcontroller.
All communication is initiated by the host. The SAF-TE processor acts only 
in target mode. The SAF-TE processor should be periodically polled by the 
host approximately every 2 to 10 seconds.