DLP-576
Page 1 of 2
TBOS CHASSIS DAISY-CHAINING
Summary: 
This procedure provides instructions for daisy-chaining one TBOS link to several
chassis configured for compressed TBOS. Up to four chassis can be connected in this manner.
1) Assign a different address in the range 0 through 7 to each of the compressed displays
available on the link.
Reference: 
 Serial Port Configuration
2) Make sure each chassis in the chain has an MPU installed.
Reference: 
 MPU Installation and Testing
Reference: 
 MPU Replacement and Testing
3) Remove the termination strap from the Berg jumper pins labeled "JD 13" from each MPU's
4) Make connections between chassis: from each Port 1 Tx
 to Tx
; from each Port 1 Tx+ to
Tx+; from each Port 1 Rx
 to Rx
; and from each Port 1 Rx+ to Rx+, as shown in
under Related Publications at the beginning of this manual, for wiring instructions.
Stop! You have completed this procedure.