5-6
   Preliminary January 4, 2001   
MAX 6000/3000 Network Configuration Guide
Configuring Frame Relay
Defining Frame Relay link operations
Link parameters
The next two parameters in Ethernet > Frame Relay > Frame Relay profile define the link 
status of the FR datalink and the link protocol to use between the MAX and the FR switch: 
Timers and event count parameters
The functions of Frame Relay timers and event counts include the following parameters in 
Ethernet > Frame Relay > Frame Relay profile
Call-by-Call
A signaling value the PRI service uses when placing a call using that 
profile.
Transit #
A dialing prefix for use in the transit network IE for PRI calling when 
going through an Interexchange Carrier (IEC). The default (null) 
causes the MAX to use any available IEC for long-distance calls.
Parameter
Specifies
Link Status Dlci
The DLCI to use for link status on the Frame Relay datalink. Specify 
DLCI0 (the default) or DLCI1023.
Link Mgmt
Link management protocol to use between the MAX and the Frame 
Relay switch. The Frame Relay administrator or service provider can 
tell you which value to use.
Parameter
Specifies
N391
Interval at which the MAX requests a Full Status Report (from 1 to 
255 seconds). Is N/A if FR Type is DCE. 
DTE N392
Number of errors, during DTE N393 monitored events, that cause the 
user side to declare the network-side procedures inactive. The value 
should be less than that of DTE N393 (from 1 to 10). DTE N.392 is N/
A when FR Type is DCE.
DTE N393
Number of DTE monitored events per testing cycle (from 1 to 10). It is 
N/A when FR Type is DCE.
DCE N392
Number of errors, during DCE N393 monitored events, that causes the 
network side to declare the user-side procedures inactive. The value 
should be less than that of DCE N393 (from 1 to 10). DCE N392 is N/
A when FR Type is DTE. 
DCE N393
DCE monitored event count (from 1 to 10). It is N/A when FR Type is 
DTE.
T391
Link Integrity Verification polling timer (from 5 to 30 seconds). The 
value should be less than that of T392. T391 is N/A when FR Type is 
DCE.