Lucent Technologies 6000 用户手册

下载
页码 586
Configuring Frame Relay
Configuring switched Frame Relay connections
MAX 6000/3000 Network Configuration Guide
 
   Preliminary January 4, 2001   
5-33
permconn-max-15 Password="ascend", User-Service=Dialout-Framed-User
    User-Name="max39",
    Framed-Protocol=FR-CIR,
    Ascend-Route-IP=Route-IP-No,
    Ascend-FR-DLCI=200,
    Ascend-FR-Profile-Name="nni-39",
    Ascend-FR-Circuit-Name="cir-42"
The following profiles define the datalinks from MAX-39 to MAX-42 and the Pipeline 130:
frdlink-max-27 Password="ascend", User-Service=Dialout-Framed-User
    Ascend-FR-Profile-Name="nni-42",
    Ascend-Call-Type=Nailed,
    Ascend-FR-Type=Ascend-FR-NNI,
    Ascend-FR-Nailed-Grp=777
frdlink-max-28 Password="ascend", User-Service=Dialout-Framed-User 
    Ascend-FR-Profile-Name="dce-p130",
    Ascend-Call-Type=Nailed,
    Ascend-FR-Type=Ascend-FR-DCE,
    Ascend-FR-Nailed-Grp=888
The next set of profiles specifies the circuit on MAX-39:
permconn-max-16 Password="ascend", User-Service=Dialout-Framed-User
    User-Name="max42"
    Framed-Protocol=FR-CIR,
    Ascend-Route-IP=Route-IP-No,
    Ascend-FR-DLCI=200,
    Ascend-FR-Profile-Name="nni-42",
    Ascend-FR-Circuit-Name="cir-39"
permconn-max-17 Password="ascend", User-Service=Dialout-Framed-User
    User-Name="p130",
    Framed-Protocol=FR-CIR,
    Ascend-Route-IP=Route-IP-No,
    Ascend-FR-DLCI=300,
    Ascend-FR-Profile-Name="dce-p130",
    Ascend-FR-Circuit-Name="cir-39"
Configuring switched Frame Relay connections
You can enable the MAX to support Frame Relay switched connections over ISDN BRI or PRI 
connections. A switched Frame Relay connection provides either a 56K or 64K connection, 
depending on the ISDN network configuration.
Overview
When a Frame Relay profile and an associated Connection profile are configured for a 
switched Frame Relay connection, the Connection profile can establish a Frame Relay session 
either by placing an outgoing call or by matching the CLID or DNIS of an incoming call. Once 
the session is established, it behaves just like a nailed Frame Relay connection with an access