Lucent Technologies 6000 用户手册

下载
页码 586
14-14
MAX 6000/3000 Network Configuration Guide
Configuring Packet Bridging
Configuring bridged connections
possible. In this situation, you should set the Netware t/o timer by setting the Netware t/o 
parameter to specify the timer in minutes. The timer begins counting down as soon as the link 
goes down. When the timer expires, the unit stops responding to watchdog packets and the 
client-server connections can be released by the server. If the WAN session reconnects before 
the end of the selected time, the timer resets.
Note:
The unit performs watchdog spoofing only for packets encapsulated in the IPX frame 
type specified in the Ethernet > Mod Config > Ether Options profile. For example, if IPX 
Frame=802.3, only logins to servers using that packet frame type are spoofed.
Example of an IPX client bridge (local clients)
In this example, the local Ethernet network supports NetWare clients, and the remote network 
supports both NetWare servers and clients, so the MAX unit requires IPX client bridging. 
When Handle IPX=Client, the unit applies a data filter that discards RIP and SAP periodic 
broadcasts at its WAN interface, but forwards RIP and SAP queries. Therefore, local clients 
can locate a NetWare server across the WAN, but routine broadcasts do not keep the 
connection up unnecessarily. 
Figure 14-4. An example of an IPX client bridged connection
To configure the Site A MAX unit in this example:
1
Make sure that the Name parameter in the System > Sys Config profile specifies a name 
for the MAX unit. This example uses the name SITEAGW for the MAX.
2
Specify the IPX frame type in the Ethernet > Mod Config > Ether Options profile. For 
example:
Ethernet
Mod Config
Ether options...
IPX Frame=802.3
3
Enable bridging and specify an authentication protocol in the Answer > PPP Options 
profile. For example:
Ethernet
Answer
PPP options...
Bridge=Yes
Recv Auth=Either
4
Open a Connection profile and set the following parameters:
Ethernet
Connections
Connection profile
Station=SITEBGW
Active=Yes
Site A 
MAX
(local)
Site B 
MAX
(remote)
WAN