Specification
 Chapter 10: VSE-6802 Serial Equalizing Distribution Amplifier Module
 Jumper and Potentiometer
Jumpers and 
Potentiometer
Name
Function
J1 Auto
Reclock/
270MHz
This jumper provides the 
selection of the reclocking mode. 
In the Auto Reclock mode, the re-
clocking circuit locks the input 
data to one of the five rates 
automatically. In 270 MHz mode, 
the reclocking circuit locks the 
input data to 270 MHz directly, 
which reduces the re-locking 
time.
J2 No-lock 
Disable
When the input data is not locked 
and J2 is set at the No Lock 
position, the contact closure port 
will not report the no-locking 
alarm.
J3 No-data 
Disable
When the input data is not 
present and J3 is set at the 
N_DATA position, the contact 
closure circuit will not report the 
alarm of the data absence out.
R2 (pot)
Threshold 
Level
This pot is designed for the 
adjustment of the input data 
threshold level in the input level 
detect circuit. Used to eliminate 
the maximum cable length. (The 
shorter the cable, the less jitter).