Card Setup 
OMG-ULTRA-COMM422 
Page 10 
Clock Modes 
The  OMG-ULTRA-COMM422 employs a unique clocking option that allows the 
end user to select from divide by 4, divide by 2 and divide by 1 clocking modes. 
These modes are selected at Headers J1C through J4C.  
To select the Baud rates commonly associated with COM: ports  (i.e. 2400, 4800, 
9600, 19.2, … 115.2K Bps ) place the jumper in the divide by 4 mode (silk-screen 
DIV4).  
DIV1
DIV2
DIV4
 
Figure 12 - Clocking Mode 'Divide By 4’ 
To double these rates up to a maximum rate for 230.4K bps place the jumper in 
the divide by 2 (silk-screen DIV2) position.  
DIV1
DIV2
DIV4
 
Figure 13 - Clocking Mode 'Divide By 2’ 
To select the maximum data rate (460.8K bps) place the jumper in the divide by 1 
(silk-screen DIV1) position.  
DIV1
DIV2
DIV4
 
Figure 14 - Clocking Mode 'Divide By 1’