Sun Microsystems T3 用户手册

下载
页码 88
60
Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001
Switch connection where the FC-AL from the array is connected to a switch on
the same network as the data host.
Administration Path
For the administration path, each controller unit has an Ethernet connector. For each
installed controller, an Ethernet connection and IP address are required. The
administration server uses this link to set up and manage the arrays using Sun
StorEdge Component Manager software.
Note –
In a partner group, only one of the two Ethernet connections is active at any
time. The second Ethernet connection is used for redundancy.
Connecting Partner Groups
The array also has two interconnect cards that are used to connect the array in a
partner group. These interconnect cards have two ports (in and out).
Note –
Partner groups are not supported in Sun Cluster 2.2.
Note –
In a workgroup (standalone) configuration, these interconnect cards cannot
be used to connect to the administrative console or to the application host. These
interconnect cards are used solely for ensuring redundancy and failover mechanisms
in partner groups.
and
show a Sun StorEdge T3 and T3+ array with a controller
card and interconnect cards.