Emerson PMT1 用户手册
Overview:
Additional Information
PmT1 and PmE1 User’s Manual
10002367-02
1-4
Table 1-1:
Address Summary
ADDITIONAL INFORMATION
This section lists the PmT1 and PmE1 hardware’s regulatory certifications and briefly dis-
cusses the terminology and notation conventions used in this manual. It also lists general
technical references.
cusses the terminology and notation conventions used in this manual. It also lists general
technical references.
Mean time between failures (MTBF) is listed in the following table:
Table 1-2:
MTBF Hours
Product Certification
The PmT1 and PmE1 hardware has been tested to comply with various safety, immunity,
and emissions requirements as specified by the Federal Communications Commission
(FCC), Underwriters Laboratories (UL), and others. The following table summarizes this
compliance:
and emissions requirements as specified by the Federal Communications Commission
(FCC), Underwriters Laboratories (UL), and others. The following table summarizes this
compliance:
Physical Address
(hex):
(hex):
Access
Mode:
Mode:
Description:
See
Page:
Page:
FFF0,0000
R
Flash/ROM Socket
FF00,0000
R/W
CPU registers
C101,0000
—
reserved
—
C100,0000
R/W
PMC/PCI Interface registers
C000,0200
—
reserved
—
C000,0180
R
Board Configuration register
C000,0080
—
reserved
—
C000,000C
R
Conventional Interrupt register
C000,0000
R
Interrupt Vector register
8000,0000
—
reserved
—
6000,0000
R/W
PCI I/O Space
4000,000
R/W
PCI Memory Space
C101,0000
—
reserved
—
0000,0000
R/W
DRAM
Product
Calculation Method:
Hours:
PmT1
Bellcore Issue 5
344,234
PmE1
Telecordia Issue 1
1,333,573